302F/EG-FJ
6"x4"x6" to 8"x6"x8"
Gear Operated, Full Jacketed
|
 |
Full
jacketing with oversize flanges should be considered when
maximum heating or cooling is required without regard to
uniformity of temperature
The
advantages of using a partial jacket,
should be considered before making this selection.
click here to go to Fluoroseal
Jacketed Valves section.
Dimensions to ANSI
B16.5-1988 & B16.10-1986
|
Size |
Units |
L |
H |
D |
BC |
g |
b |
f |
d |
Q |
N |
6"x4"
x6"EG |
inch |
10.5 |
11.50 |
11.00 |
9.50 |
8.50 |
1.00 |
0.06 |
0.88 |
9.00 |
8 |
|
mm |
266.7 |
292 |
279.4 |
241.3 |
215.9 |
25.4 |
1.6 |
22.4 |
228.6 |
8"x6"
x8"EG |
inch |
11.5 |
13.00 |
13.50 |
11.75 |
10.63 |
1.13 |
0.06 |
0.88 |
12.00 |
8 |
|
mm |
292.1 |
330 |
342.9 |
298.5 |
269.8 |
28.7 |
1.6 |
22.4 |
304.8 |
Full jacket 3 way valves are also
available. Consult your nearest FluoroSeal Distributor for these
and other special requirements.
|
 |
|